{"id":1189,"date":"2026-11-16T18:42:19","date_gmt":"2026-11-16T10:42:19","guid":{"rendered":"https:\/\/dby9002.com.tw\/?page_id=1189"},"modified":"2026-11-20T13:42:24","modified_gmt":"2026-11-20T05:42:24","slug":"textile-dyeing-wastewater","status":"publish","type":"page","link":"https:\/\/dby9002.com.tw\/en\/textile-dyeing-wastewater\/","title":{"rendered":"Treatment of sewage with aeration and sludge dehydration equipment"},"content":{"rendered":"<div class=\"et_pb_section_0 et_pb_section et_section_regular et_flex_section\">\n<div class=\"et_pb_row_0 et_pb_row et_pb_gutters3 et_grid_row\">\n<div class=\"et_pb_column_0 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_heading_0 et_pb_heading et_pb_module et_flex_module\"><div class=\"et_pb_heading_container\"><h1 class=\"et_pb_module_header\">Treatment of sewage with aeration and sludge dehydration equipment<\/h1><\/div><\/div>\n\n<div class=\"et_pb_text_0 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>Adjust the color of wastewater,<span>COD <\/span>With batch water quality fluctuations being significant, it is often accompanied by high temperatures and special acid-base conditions. Da Ben Ying Co. Ltd. provides configuration recommendations for standardized, chemical sludge dewatering and corrosion-resistant aeration equipment, helping dyeing manufacturers select the appropriate materials and equipment based on the characteristics of their processes.<\/p>\n<\/div><\/div>\n\n<div class=\"et_pb_group_0 et_pb_group et-last-child et_pb_module et_flex_group et_pb_css_mix_blend_mode_passthrough\">\n<div class=\"et_pb_module et_pb_button_module_wrapper et_pb_button_0_wrapper\"><a class=\"et_pb_button_0 et_pb_button et_pb_bg_layout_light et_pb_module et_block_module\" href=\"https:\/\/dby9002.com.tw\/en\/r-d\/\"><span class=\"et-pb-parallax-content\">Consulting on the planning and evaluation of original water experiments<\/span><\/a><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_column_1 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_image_0 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewate6-a.jpg\" title=\"watewate6-a\" width=\"800\" height=\"556\" srcset=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewate6-a.jpg 800w, https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewate6-a-480x334.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 800px, 100vw\" class=\"wp-image-1194\" \/><\/span><\/div>\n\n<div class=\"et_pb_text_1 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>The illustration shows a schematic layout for the application of a treatment plant for dyeing wastewater aeration and sludge dewatering equipment.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_section_1 et_pb_section et_section_regular et_flex_section\">\n<div class=\"et_pb_row_1 et_pb_row et_pb_gutters3 et_grid_row\">\n<div class=\"et_pb_column_2 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_image_1 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewate6-b.jpg\" title=\"watewate6-b\" width=\"800\" height=\"556\" srcset=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewate6-b.jpg 800w, https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewate6-b-480x334.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 800px, 100vw\" class=\"wp-image-1195\" \/><\/span><\/div>\n<\/div>\n\n<div class=\"et_pb_column_3 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_heading_1 et_pb_heading et_pb_module et_flex_module\"><div class=\"et_pb_heading_container\"><h2 class=\"et_pb_module_header\">Batch of wastewater treated with various chemicals and water quality fluctuations<\/h2><\/div><\/div>\n\n<div class=\"et_pb_text_2 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>The dyeing process involves multiple steps such as dyeing, printing, water washing, and finishing. The types and quantities of dyes, auxiliaries, and the water used vary greatly between batches and different color schemes and fabric materials, resulting in chromatic variations in wastewater.<span>pH <\/span>Value and chemical oxygen demand (<span>COD<\/span>These fluctuations in water quality may vary significantly from one time period to another. This batch-based variation in water quality is the most challenging aspect to consider when designing wastewater treatment systems.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_2 et_pb_row et_pb_gutters3 et_grid_row\">\n<div class=\"et_pb_column_4 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_heading_2 et_pb_heading et_pb_module et_flex_module\"><div class=\"et_pb_heading_container\"><h2 class=\"et_pb_module_header\">Equalization and pH control\u2014not a single step can be skipped<\/h2><\/div><\/div>\n\n<div class=\"et_pb_text_3 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>Batch fluctuations in wastewater treatment are significant; it is recommended to install a mixing basin to mix and homogenize the wastewater from different batches, and adjust as needed.<span> pH <\/span>It is advisable to avoid the direct impact of strong acid or strong alkali waste water on the downstream biological treatment system, as this may affect the microbial activity and the treatment efficiency.<\/p>\n<\/div><\/div>\n<\/div>\n\n<div class=\"et_pb_column_5 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_image_2 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewatec.jpg\" title=\"watewatec\" width=\"800\" height=\"556\" srcset=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewatec.jpg 800w, https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewatec-480x334.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 800px, 100vw\" class=\"wp-image-1196\" \/><\/span><\/div>\n\n<div class=\"et_pb_text_4 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p style=\"text-align: center;\">The actual scene of wastewater mixing, homogenizing and aeration within the tank<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_3 et_pb_row et_pb_gutters3 et_grid_row\">\n<div class=\"et_pb_column_6 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_image_3 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewate6-e.jpg\" title=\"watewate6-e\" width=\"800\" height=\"556\" srcset=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewate6-e.jpg 800w, https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewate6-e-480x334.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 800px, 100vw\" class=\"wp-image-1197\" \/><\/span><\/div>\n\n<div class=\"et_pb_text_5 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p style=\"text-align: center;\">Real-life view of industrial dehydration equipment or sludge treatment machine<\/p>\n<\/div><\/div>\n<\/div>\n\n<div class=\"et_pb_column_7 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_heading_3 et_pb_heading et_pb_module et_flex_module\"><div class=\"et_pb_heading_container\"><h2 class=\"et_pb_module_header\">How to remove water from sludge after chemical treatment<\/h2><\/div><\/div>\n\n<div class=\"et_pb_text_6 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>Treatment of wastewater often requires the addition of coagulants and chemical precipitation to remove color and some pollutants. This process produces chemical sludge. The nature of this sludge differs from conventional activated sludge; the ease of dehydration and the required dosage formulation may also have significant differences. It is recommended to confirm the appropriate dehydration method through a test using raw water; for details, see <span><a href=\"\/en\/products\/sludge-dewatering\/hs500\/\">HS500<\/a><\/span>\u3001<span><a href=\"\/en\/products\/sludge-dewatering\/hs800\/\">HS800<\/a><\/span> Product page.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_4 et_pb_row et_pb_gutters3 et_grid_row\">\n<div class=\"et_pb_column_8 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_heading_4 et_pb_heading et_pb_module et_flex_module\"><div class=\"et_pb_heading_container\"><h2 class=\"et_pb_module_header\">Exhaust ventilation equipment and DO management<\/h2><\/div><\/div>\n\n<div class=\"et_pb_text_7 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>If the wastewater treatment process includes a biological treatment stage, the aeration equipment must maintain the dissolved oxygen level in the pond (<span>DO<\/span>Maintain within appropriate range to assist microorganisms in decomposing organic pollutants, see details.<span><a href=\"\/en\/products\/wastewater-aeration\/\">Sewage aeration equipment<\/a><\/span>The temperature and chemical residues in the treated wastewater pose additional challenges for the materials of the aeration equipment; when selecting the materials, compatibility with the equipment must be evaluated simultaneously.<\/p>\n<\/div><\/div>\n<\/div>\n\n<div class=\"et_pb_column_9 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_image_4 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewate6-f.jpg\" title=\"watewate6-f\" width=\"800\" height=\"556\" srcset=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewate6-f.jpg 800w, https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/watewate6-f-480x334.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 800px, 100vw\" class=\"wp-image-1198\" \/><\/span><\/div>\n\n<div class=\"et_pb_text_8 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p style=\"text-align: center;\">Maintaining dissolved oxygen levels within appropriate ranges and 'helping microorganisms decompose organic pollutants'<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_5 et_pb_row et_pb_gutters3 et_grid_row\">\n<div class=\"et_pb_column_10 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_image_5 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/image-d2b1e78d-ee1c-4789-a51f-5213eb344acd-976x688.jpeg\" alt=\"AI Image\" width=\"976\" height=\"688\" srcset=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/image-d2b1e78d-ee1c-4789-a51f-5213eb344acd-976x688.jpeg 976w, https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/image-d2b1e78d-ee1c-4789-a51f-5213eb344acd-976x688-480x338.jpeg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 976px, 100vw\" class=\"wp-image-1264\" title=\"watewate6-g\" \/><\/span><\/div>\n<\/div>\n\n<div class=\"et_pb_column_11 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_heading_5 et_pb_heading et_pb_module et_flex_module\"><div class=\"et_pb_heading_container\"><h2 class=\"et_pb_module_header\">High temperature, acidity and material selection<\/h2><\/div><\/div>\n\n<div class=\"et_pb_text_9 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>Sewage treatment often involves high temperatures and specific acid-base conditions. The choice of equipment material must be extremely careful. Da Ben Ying Co. Ltd. provides stainless steel (such as<span> SUS316<\/span>In addition to nylon and other material options, the actual choice should be based on the temperature range of the wastewater.<span>pH <\/span>For the determination of value and main chemical components, see details.<span><a href=\"\/en\/products\/wastewater-aeration\/stainless-steel-diffuser\/\">Stainless steel exhaust equipment<\/a><\/span>\u8207<span><a href=\"\/en\/products\/wastewater-aeration\/nylon-diffuser\/\">Nylon ventilation equipment<\/a><\/span>Page.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_6 et_pb_row et_pb_gutters3 et_grid_row\">\n<div class=\"et_pb_column_12 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_heading_6 et_pb_heading et_pb_module et_flex_module\"><div class=\"et_pb_heading_container\"><h2 class=\"et_pb_module_header\">Supplementation experiments, mud cakes, and operational data<\/h2><\/div><\/div>\n\n<div class=\"et_pb_text_10 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>The dehydration effect of sludge conditioning is greatly influenced by the chemical treatment method, the type of drug, and the characteristics of the sludge. It is recommended that before a formal quote is issued, samples of the original sludge be taken from the site and sent to the laboratory for drug formulation and dehydration testing. After confirming the actual solid-liquid separation effect, the equipment specifications and operating parameters should then be determined.<\/p>\n<\/div><\/div>\n<\/div>\n\n<div class=\"et_pb_column_13 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_image_6 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/1.4.jpg\" title=\"1.4\" width=\"868\" height=\"552\" srcset=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/1.4.jpg 868w, https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/1.4-480x305.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 868px, 100vw\" class=\"wp-image-283\" \/><\/span><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_7 et_pb_row et_pb_gutters3 et_grid_row\">\n<div class=\"et_pb_column_14 et_pb_column et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_image_7 et_pb_image et_pb_module et_flex_module\"><span class=\"et_pb_image_wrap\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/P1693205037952.jpg\" title=\"P1693205037952\" width=\"1024\" height=\"575\" srcset=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/P1693205037952.jpg 1024w, https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/P1693205037952-980x550.jpg 980w, https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/P1693205037952-480x270.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1024px, 100vw\" class=\"wp-image-485\" \/><\/span><\/div>\n<\/div>\n\n<div class=\"et_pb_column_15 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_animated\">\n<div class=\"et_pb_heading_7 et_pb_heading et_pb_module et_flex_module\"><div class=\"et_pb_heading_container\"><h2 class=\"et_pb_module_header\">Case studies and water quality assessment<\/h2><\/div><\/div>\n\n<div class=\"et_pb_text_11 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>The processes and chemical usage methods of different dyeing factories vary greatly, and the actual processing effect will depend on the case-by-case evaluation; relevant cases (after obtaining customer authorization) will be announced successively on the website.<span><a href=\"\/en\/projects\/sludge-dewatering\/\">Case of sludge dehydration<\/a><\/span>Page.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_section_2 et_pb_section et_section_regular et_flex_section\" id=\"faq-consult\">\n<div class=\"et_pb_row_8 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_16 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_heading_8 et_pb_heading et_pb_module et_flex_module\"><div class=\"et_pb_heading_container\"><h2 class=\"et_pb_module_header\">Common problems and on-site consultations<\/h2><\/div><\/div>\n\n<div class=\"et_pb_text_12 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><p>Provide objective engineering explanations for the most frequently raised concerns regarding paper-making wastewater.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_row_9 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_17 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_accordion_0 et_pb_accordion et_pb_module et_flex_module\">\n<div class=\"et_pb_accordion_item_0 et_pb_accordion_item et_pb_toggle et_pb_module et_pb_toggle_open et_flex_module\"><h5 class=\"et_pb_toggle_title\">Do aeration equipment for treating wastewater have to be made of stainless steel? <\/h5><div class=\"et_pb_toggle_content et_flex_module\"><p>Not necessarily. It depends on the actual waste water temperature, acidity\/alkalinity, and chemical composition; in some cases, nylon material is also suitable. We recommend providing water quality data for evaluation by a technician.<\/p>\n<\/div><\/div>\n\n<div class=\"et_pb_accordion_item_1 et_pb_accordion_item et_pb_toggle et_pb_module et_pb_toggle_close et_flex_module\"><h5 class=\"et_pb_toggle_title\">Will the dehydration effect of treating sludge be worse than that of ordinary sludge?<\/h5><div class=\"et_pb_toggle_content et_flex_module\"><p>The ease with which sludge can be dewatered and the required formulation of the treatment agent will vary depending on the chemical treatment method and the characteristics of the sludge. It is recommended to confirm the actual effect through a test using raw water; it is not advisable to directly apply the expected performance of general activated sludge.<\/p>\n<\/div><\/div>\n\n<div class=\"et_pb_accordion_item_2 et_pb_accordion_item et_pb_toggle et_pb_module et_pb_toggle_close et_flex_module\"><h5 class=\"et_pb_toggle_title\">Can the color of treated wastewater be removed by aeration equipment? <\/h5><div class=\"et_pb_toggle_content et_flex_module\"><p>The aeration equipment is primarily responsible for supplying the dissolved oxygen needed for biological treatment. To remove color, other treatment units such as chemical treatment (e.g., coagulation and oxidation) are usually required. It is recommended to consult a professional environmental engineer to plan the overall process.<\/p>\n<\/div><\/div>\n\n<div class=\"et_pb_accordion_item_3 et_pb_accordion_item et_pb_toggle et_pb_module et_pb_toggle_close et_flex_module\"><h5 class=\"et_pb_toggle_title\">Which water testing equipment is suitable for dyeing plants to apply for? <\/h5><div class=\"et_pb_toggle_content et_flex_module\"><p>It is recommended that sludge dehydration and aeration equipment be evaluated together, and the temperature of the wastewater be provided.<span>pH <\/span>Values and main chemical composition data for engineers to plan suitable treatment solutions.<\/p>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"et_pb_section_3 et_pb_section et_section_regular et_flex_section\" id=\"faq\">\n<div class=\"et_pb_row_10 et_pb_row et_flex_row\">\n<div class=\"et_pb_column_18 et_pb_column et-last-child et_flex_column et_pb_css_mix_blend_mode_passthrough et_flex_column_24_24 et_flex_column_24_24_tablet et_flex_column_24_24_phone\">\n<div class=\"et_pb_text_13 et_pb_text et_pb_bg_layout_light et_pb_module et_flex_module\"><div class=\"et_pb_text_inner\"><div class=\"double-border-box\">\n<p>\u200b<strong>Next step:<\/strong> <span><a href=\"\/en\/products\/sludge-dewatering\/hs500\/\">HS500<\/a><\/span> \uff5c <span><a href=\"\/en\/products\/wastewater-aeration\/stainless-steel-diffuser\/\">Stainless steel exhaust equipment<\/a><\/span> \uff5c <span><a href=\"\/en\/products\/wastewater-aeration\/nylon-diffuser\/\">Nylon ventilation equipment<\/a><\/span> \uff5c <span><a href=\"\/en\/industries\/electroplating-wastewater\/\">Electrolytic wastewater treatment<\/a><\/span> \uff5c  <a href=\"https:\/\/line.me\/ti\/p\/Q7y3m-Jkrk\">For water quality assessment requests, please ask LINE.<\/a><\/p>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":8,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"difl_page_category":[],"class_list":["post-1189","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/pages\/1189","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/comments?post=1189"}],"version-history":[{"count":14,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/pages\/1189\/revisions"}],"predecessor-version":[{"id":1764,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/pages\/1189\/revisions\/1764"}],"wp:attachment":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/media?parent=1189"}],"wp:term":[{"taxonomy":"difl_page_category","embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/difl_page_category?post=1189"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}