{"id":1343,"date":"2026-11-18T09:46:45","date_gmt":"2026-11-18T01:46:45","guid":{"rendered":"https:\/\/dby9002.com.tw\/?p=1343"},"modified":"2026-11-18T20:32:57","modified_gmt":"2026-11-18T12:32:57","slug":"hs500-vs-hs800","status":"publish","type":"post","link":"https:\/\/dby9002.com.tw\/en\/blog\/hs500-vs-hs800\/","title":{"rendered":"What is the difference between HS500 and HS800? Sludge dewatering machines cannot be judged by the hourly tonnage alone."},"content":{"rendered":"<h2 class=\"wp-block-heading\">What is the difference between HS500 and HS800? Sludge dewatering machines cannot be judged by the hourly tonnage alone.<\/h2>\n\n\n\n<p class=\"dby-blockquote wp-block-paragraph\"><strong>The HS500 and HS800 are both Da Ben Ying Co. Ltd. rotary drum sludge dewatering machines from Daobenying. The main difference lies in their processing capacity:<\/strong>The official website indicates that the HS500 produces approximately 200\u2013500 kilograms of sludge cake per hour, while the HS800 produces approximately 400\u2013800 kilograms per hour. However, the processing volume of both models is within a range; the actual figures will vary depending on the original sludge concentration, sludge properties, and processing conditions, so when selecting the model, it is necessary to first calculate the dry sludge load of the plant, rather than simply comparing the hourly tonnage.<\/p>\n\n\n\n<div class=\"wp-block-columns is-not-stacked-on-mobile is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/w10-11.jpg\" alt=\"\" class=\"wp-image-1312\" srcset=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/w10-11.jpg 800w, https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/w10-11-480x360.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 800px, 100vw\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/w10-12.jpg\" alt=\"\" class=\"wp-image-1531\" srcset=\"https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/w10-12.jpg 800w, https:\/\/dby9002.com.tw\/wp-content\/uploads\/2026\/11\/w10-12-480x360.jpg 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) 800px, 100vw\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"blog-post-container\">\n\n    <!-- \u6587\u7ae0\u5927\u6a19\u984c -->\n\n\n    <p class=\"wp-block-paragraph\">This article explains the differences in specifications between the HS500 and HS800, why processing capacity varies, and how to make judgments when the two models overlap in terms of processing capacity based on expansion plans, space, and operating hours.<\/p>\n\n    <h2>What are the differences between the HS500 and HS800 specifications?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>The core difference between the HS500 and HS800 is the level of processing capacity: the HS800\u2019s sludge cake production range is approximately 1.6\u20132 times that of the HS500, corresponding to a larger volume of wastewater treatment.<\/strong>Both are of the rolling bed design and are entirely manufactured in Taiwan. They are suitable for industries with similar production processes and operating logic.<\/p>\n\n    <!-- \u8868\u683c\u5340\u584a\uff08\u624b\u6a5f\u7248\u53ef\u5de6\u53f3\u89f8\u63a7\u6ed1\u52d5\uff09 -->\n    <div class=\"dby-table-wrapper\">\n        <table class=\"dby-custom-table\">\n            <thead>\n                <tr>\n                    <th>Comparison items<\/th>\n                    <th>HS500<\/th>\n                    <th>HS800<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td>Dehydration type<\/td>\n                    <td>Roll-bed type<\/td>\n                    <td>Roll-bed type<\/td>\n                <\/tr>\n                <tr>\n                    <td>The official website indicates the production of sludge cakes.<\/td>\n                    <td>About 200\u2013500 kg\/h<\/td>\n                    <td>About 400\u2013800 kg\/h<\/td>\n                <\/tr>\n                <tr>\n                    <td>The official website indicates the corresponding sewage volume.<\/td>\n                    <td>About 7 tons per hour<\/td>\n                    <td>About 15 tons per hour or more<\/td>\n                <\/tr>\n                <tr>\n                    <td>Place of manufacture<\/td>\n                    <td>Taiwan<\/td>\n                    <td>Taiwan<\/td>\n                <\/tr>\n                <tr>\n                    <td>Suitable for the situation<\/td>\n                    <td>Small and medium-sized sludge volume, capable of operating for a long time<\/td>\n                    <td>The sludge volume is large, operating hours are limited, or there are plans to expand production.<\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n    <\/div>\n\n    <p class=\"wp-block-paragraph\">For product details, please refer to the HS500 Sludge Dewatering Machine product page and the HS800 Sludge Dewatering Machine product page.<\/p>\n\n    <h2>Why is the sludge dehydration machine\u2019s processing capacity variable, not a fixed number?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>The treatment capacity of the sludge dewatering machine will vary depending on the original sludge conditions, because the machine actually processes the solid matter in the sludge; the content of solid matter and the dewatering performance vary from one plant to another.<\/strong>With the same HS500 unit, for sludge with high concentration and high tendency to volatilize, the processing concentration may approach the upper limit; for sludge with low concentration, containing oil or fine particles, the processing concentration may fall below the lower limit.<\/p>\n\n    <p class=\"wp-block-paragraph\">Specifically, the four main factors that affect the processing volume are:<\/p>\n\n    <!-- \u5217\u8868\u5340\u584a -->\n    <div class=\"dby-blockquote\">\n        <ul class=\"\">\n            <li><strong>Original clay concentration<\/strong>The higher the concentration, the more solid matter enters the tank per hour, and the more sludge cake is produced.<\/li>\n            <li><strong>Characteristics of sludge<\/strong>The difficulty of dewatering biological sludge, chemical sludge, fibrous sludge, and oil-containing sludge varies.<\/li>\n            <li><strong>Remedial therapy<\/strong>The type of coagulant and the amount of addition will affect whether the sludge can form a solid sludge cake.<\/li>\n            <li><strong>Sludge cake water content target<\/strong>Higher demands for water yield usually require longer dehydration times, and production per hour may decrease.<\/li>\n        <\/ul>\n    <\/div>\n\n    <p class=\"wp-block-paragraph\">This is also why the \"several tons per hour\" cannot be directly compared. For a complete algorithm for handling quantities, please refer to the related articles.<\/p>\n\n    <h2>How do you convert kilograms of sludge cake into the amount of dry sludge?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>The weight of sludge cake \u00d7 the solid content of the sludge cake = the dry sludge volume.<\/strong>The sludge cake yield is the weight of the water-containing material; to compare it with the daily dry sludge volume of the plant, it must first be converted into dry solids.<\/p>\n    \n    <p class=\"wp-block-paragraph\">To illustrate the calculation, assuming the sludge cake has a solid content of 20%, each hour of 200\u2013500 kilograms of sludge cake corresponds to approximately 40\u2013100 kilograms of dry solid matter per hour; if the solid content is 25%, it corresponds to approximately 50\u2013125 kilograms of dry solid matter per hour. The actual solid content must be based on the results of the test conducted by the relevant manufacturer; this calculation is only intended to illustrate that \u201cthe units must be consistent in order to compare.\u201d<\/p>\n\n    <h2>How to determine which HS500 or HS800 model is suitable for your plant?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>To determine which HS500 or HS800 model to choose, you should first confirm the daily dry sludge volume, the daily operating hours, and the future expansion needs. Based on the calculated hourly load for each model, this is the model to prioritize.<\/strong>It is recommended to evaluate according to the following steps:<\/p>\n\n    <div class=\"dby-content-box\">\n        <ol class=\"wp-block-list\">\n            <li>Calculate the daily dry sludge volume (daily sludge discharge volume \u00d7 original sludge concentration).<\/li>\n            <li>Confirm the daily operating hours and convert it to the dry solid load per hour.<\/li>\n            <li>Plus about 20\u201330% design leeway.<\/li>\n            <li>Converting the load into sludge cake production, comparing the processing area of the two models.<\/li>\n            <li>Confirm the actual performance by testing sludge samples or conducting in-situ trials.<\/li>\n        <\/ol>\n    <\/div>\n\n    <div class=\"dby-table-wrapper\">\n        <table class=\"dby-custom-table\">\n            <thead>\n                <tr>\n                    <th>Situation at the scene<\/th>\n                    <th>Priority evaluation model<\/th>\n                    <th>Reason for judgment<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td>Small sludge volume, capable of operating automatically for a long time.<\/td>\n                    <td>HS500<\/td>\n                    <td>Extended operating hours allow for the daily workload to be handled.<\/td>\n                <\/tr>\n                <tr>\n                    <td>Large sludge volume, only able to operate during the day<\/td>\n                    <td>HS800<\/td>\n                    <td>The daily workload needs to be handled within a short time.<\/td>\n                <\/tr>\n                <tr>\n                    <td>The load is placed near the upper limit of the HS500.<\/td>\n                    <td>HS800<\/td>\n                    <td>Maintain a margin of safety to avoid long-term overload operation<\/td>\n                <\/tr>\n                <tr>\n                    <td>There are plans to expand production within one to two years<\/td>\n                    <td>HS800<\/td>\n                    <td>The choice criterion is the amount of sludge produced after expansion.<\/td>\n                <\/tr>\n                <tr>\n                    <td>Limited installation space and low load<\/td>\n                    <td>HS500<\/td>\n                    <td>Prefer models that meet demand, avoiding oversized ones.<\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n    <\/div>\n\n    <h2>How should we decide when two models overlap in terms of processing capacity?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>When the hourly load falls within the range that both models can cover, it is recommended to prioritize the \"long-term operating margin\" rather than the equipment price difference.<\/strong>Keeping the HS500 running close to its maximum capacity for long periods of time makes it difficult to handle when the season is busy or the original mud concentration rises; choosing the HS800 allows for room for adjustment.<\/p>\n\n    <p class=\"wp-block-paragraph\">Conversely, if sludge volume is stable and the plant can accommodate longer operating times, the HS500 may be more suitable in terms of capital investment and floor space. The decision regarding overlapping zones should be made in conjunction with the equipment supplier after comparing the operating times, electricity consumption, dosage, and labor costs for the two configurations.<\/p><br\/>\n\n    <h2>Common problems<\/h2>\n\n    <!-- Q&A \u5340\u584a -->\n    <div class=\"dby-qa-container\">\n        <details class=\"dby-qa-item\">\n            <summary>Are the HS500 and HS800 operated the same way?<\/summary>\n            <p>The HS500 and HS800 are both roller-type sludge dewatering machines with similar operating logic. The main differences lie in the processing capacity levels. Both models feature automated operation design, with key daily operations including checking the incoming sludge condition, adjusting the dosage, and discharging the sludge cake. For practical operation and maintenance details, it is recommended to follow the operating instructions and guidance from the technical personnel when commissioning the machines.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>With a sewage flow of 7 tons per hour, should I choose the HS500?<\/summary>\n            <p>The hourly wastewater volume is only one of several factors to consider when choosing a model. Two factories with the same wastewater volume may produce significantly different amounts of dry sludge if the original mud concentration and sludge properties are different. It is recommended to first calculate the daily dry sludge volume and then combine it with the daily operating hours to determine the stable range for each model\u2019s hourly load.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>When processing volumes overlap, is it cheaper to choose a smaller one?<\/summary>\n            <p>Choosing a smaller model can reduce the equipment investment, but if it is operated close to full capacity for a long period of time, it may require extending operating hours or increasing manpower. In peak seasons, it is also more likely to be difficult to handle all the work. When evaluating, it is recommended to compare the equipment costs, operating hours, electricity consumption, medication, and labor costs of the two models to determine the total cost over three to five years.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>Does the sludge cake\u2019s water content change depending on the model?<\/summary>\n            <p>The water content of sludge cake mainly depends on the sludge properties, processing and operation conditions, rather than just the model size. For the same type of sludge, under HS500 and HS800 conditions with suitable processing conditions and load, the water content may be close to the stated value. To determine the actual water content, the most reliable method is to test the sludge samples or conduct in-situ testing.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>If we expand production in the future, can we add another machine?<\/summary>\n            <p>Depending on the scale of expansion, you can consider adding additional machines or choosing to start with models with higher processing capacity. The advantage of adding additional machines is that they can be invested in installments and some processing capacity can be retained during maintenance. Choosing a large model at one time can reduce the footprint and piping configuration. It is recommended to include the future sludge volume for the next two to three years when making the initial selection.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>Do I need to provide a sludge sample before selecting a model?<\/summary>\n            <p>It is recommended to provide samples of sludge. These samples can be used to confirm the dehydration properties, the appropriate coagulant, and the expected water content of the sludge cake. This will help the model recommendations to be more closely aligned with reality. If samples cannot be provided, at least the daily sludge discharge volume, original sludge concentration, industry-specific information, and current dehydration methods should be prepared.<\/p>\n        <\/details>\n    <\/div>\n\n    <!-- \u5e95\u90e8\u884c\u52d5\u547c\u7c72 (CTA) \u5340\u584a\uff1a\u6307\u5b9a\u6df1\u7da0\u8272\u80cc\u666f\u8207\u767d\u5b57 -->\n    <div class=\"blog-cta-box\">\n        <h3>Let Da Ben Ying Co. Ltd. help compare the HS500 and HS800<\/h3>\n        <p>Not sure if your plant is suitable for HS500 or HS800? Please provide the daily sludge volume, original sludge concentration, industry-specific requirements, and operating hours. The Da Ben Ying Co. Ltd. Technical Team can help calculate the hourly load and arrange sludge testing or on-site evaluation.<\/p>\n        <ul>\n            <li>Contact us: Da Ben Ying Co. Ltd. Contact Form<\/li>\n            <li>Email\uff1akty9002@gmail.com<\/li>\n            <li>Free phone number: 0800-216899<\/li>\n        <\/ul>\n        <a href=\"https:\/\/www.kty9002.com.tw\/paper\/contact_index.php?title_id=6593\" class=\"blog-cta-btn\">Go to fill out the consultation form<\/a>\n    <\/div>\n\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><br><\/p>","protected":false},"excerpt":{"rendered":"<p>HS500 \u8207 HS800 \u5dee\u5728\u54ea\uff1f\u6c61\u6ce5\u812b\u6c34\u6a5f\u4e0d\u80fd\u53ea\u7528\u6bcf\u5c0f\u6642\u5678\u6578\u5224\u65b7 HS500 \u8207 HS800 \u90fd\u662f\u5927\u672c\u7469\u7684 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[18],"tags":[],"class_list":["post-1343","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/posts\/1343","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/comments?post=1343"}],"version-history":[{"count":8,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/posts\/1343\/revisions"}],"predecessor-version":[{"id":1534,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/posts\/1343\/revisions\/1534"}],"wp:attachment":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/media?parent=1343"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/categories?post=1343"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/tags?post=1343"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}