{"id":1494,"date":"2026-11-18T17:20:01","date_gmt":"2026-11-18T09:20:01","guid":{"rendered":"https:\/\/dby9002.com.tw\/?p=1494"},"modified":"2026-11-18T20:41:12","modified_gmt":"2026-11-18T12:41:12","slug":"maintenance-of-aeration-diffusers","status":"publish","type":"post","link":"https:\/\/dby9002.com.tw\/en\/blog\/aeration-diffusers-maintenance\/","title":{"rendered":"Why do aeration discs get blocked or cracked? The causes, materials, and maintenance tips at a glance"},"content":{"rendered":"<div class=\"blog-post-container\">\n\n    <!-- \u6587\u7ae0\u5927\u6a19\u984c -->\n    <h2>Why do aeration discs get blocked or cracked? The causes, materials, and maintenance tips at a glance<\/h2>\n    \n    <!-- \u5f15\u6587\u5340\u584a -->\n    <p class=\"dby-blockquote wp-block-paragraph\"><strong>The most common causes of aeration disc blockage are sludge recirculation during deaeration, surface fouling and biofilm adhesion, and dirty air intake from the blower; while cracks are often related to material aging, wind volume or wind temperature exceeding design limits, chemical corrosion, and installation stress.<\/strong>The most direct indicator for determining whether the aeration disc is defective is the change in the pressure (pressure loss) at the blower outlet, as well as the uniformity of the bubble distribution in the pool surface.<\/p>\n\n    <p class=\"wp-block-paragraph\">This article summarizes the common causes of air-pocket blockage and rupture, the corresponding on-site assessment methods, and the maintenance and selection points for reducing failure.<\/p>\n\n    <h2>What are the effects of a blocked degassing plate?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>When the aeration disc becomes blocked, the air-flow resistance increases, and the blower must be used at a higher pressure to supply air. This results in increased power consumption and reduced oxygen supply, and the water quality becomes unstable.<\/strong>The initial blockage is usually not easily detected because the blower is still running and the water surface still has bubbles, but dissolved oxygen may have been slowly declining.<\/p>\n    \n    <p class=\"wp-block-paragraph\">If the blockage continues to worsen, some aeration discs will no longer be able to release any air at all. This creates dead spots at the bottom of the pond, making sludge sedimentation more likely to cause anaerobic odor formation; other aeration discs that still have air can handle a larger flow rate, increasing the risk of rupture. In other words, blockage and rupture often occur in a chain reaction.<\/p>\n\n    <h2>Why does the degassing plate become blocked?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>The blockage of the aeration disc can be divided into two types: \"water-side blockage\" and \"air-side blockage\": the water side comes from sludge, encrustation, and biofilm in wastewater, while the air side comes from dust and rust particles brought in by the air supply pipe.<\/strong><\/p>\n\n    <!-- \u5217\u8868\u5340\u584a\uff1a\u6539\u7528 dby-blockquote \u6a23\u5f0f -->\n    <div class=\"dby-blockquote\">\n        <ul class=\"wp-block-list\">\n            <li><strong>Sludge returns when the flow stops<\/strong>When power outages, blower motor malfunctions, or intermittent aeration stops, sludge in the pond will flow back into the aeration vessel and air pipes under the pressure of the water, which is one of the most common causes of blockage. When the returning sludge dries and hardens inside the pipe, even if the air is re-supplied, it is difficult to completely blow it out. When selecting the aeration vessel, it is important to ensure that it has a backflow prevention design that can block the return of sludge during shutdown.<\/li>\n            <li><strong>Surface scale and biofilm<\/strong>The calcium and iron components in wastewater will form scale around the aeration holes, and microorganisms will also form biofilms on the surface of the aeration tank. Both of these will reduce the size of the aeration holes and increase the resistance to gas diffusion. Wastewater with high hardness, high iron content, or high organic load will usually form scale and biofilms at a faster rate.<\/li>\n            <li><strong>Oil and fat adhere to fiber<\/strong>Industrial wastewater from industries such as food processing, slaughtering, and paper making often contains oils and fibers, which can easily adhere to the surface of the aeration vessel or become entangled in the air outlet. With fine-pore aeration vessels, the risk of blockage is higher; it is recommended to evaluate for a larger pore size or a design that prevents blockage in the ventilation equipment.<\/li>\n            <li><strong>Air duct carries impurities into the system<\/strong>Damaged or not regularly replaced intake fan filters and corroded air ducting allow dust and rust to enter the aeration chamber with the air, clogging the air outlet holes from the inside. This type of blockage is often mistakenly mistaken for a water-side problem; cleaning the surface of the aeration chamber does not improve the situation.<\/li>\n        <\/ul>\n    <\/div>\n\n    <h2>Why does the degassing disc break?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>The main causes of air-conditioning unit rupture include aging of the material, airflow or temperature exceeding the design range, chemical corrosion, and stress concentration caused by improper installation.<\/strong><\/p>\n\n    <div class=\"dby-blockquote\">\n        <ul class=\"wp-block-list\">\n            <li><strong>Material aging<\/strong>After prolonged use, rubber film strips become hardened and lose elasticity, resulting in cracks.<\/li>\n            <li><strong>Excessive wind speed<\/strong>After some aeration discs become blocked, the remaining aeration discs distribute more airflow, which makes them easily tear when exceeding the design range.<\/li>\n            <li><strong>The temperature is too high<\/strong>The air temperature at the blower outlet is higher. If the material of the air supply pipe or the air-blowing plate is not heat-resistant enough, it may deform or deteriorate.<\/li>\n            <li><strong>Chemical corrosion<\/strong>Strong acids, strong alkalis, solvents, or high concentrations of oxidizers can accelerate the deterioration of plastic and rubber materials.<\/li>\n            <li><strong>Installation and mechanical stress<\/strong>If the piping is not level, the fixing is inadequate, or the floatation and impact when the discharge tank refills cause the water to back up, it could cause the pipes to rupture or fall off.<\/li>\n        <\/ul>\n    <\/div>\n\n    <h2>How can you determine from the site whether the aeration system is malfunctioning?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>To assess the condition of the aeration system, you can simultaneously monitor the pressure of the blower, the distribution of bubbles in the pond, and changes in dissolved oxygen levels\u2014these three factors are most easily identified when compared.<\/strong><\/p>\n\n    <!-- \u8868\u683c\u5340\u584a\uff08\u624b\u6a5f\u7248\u53ef\u5de6\u53f3\u89f8\u63a7\u6ed1\u52d5\uff09 -->\n    <div class=\"dby-table-wrapper\">\n        <table class=\"dby-custom-table\">\n            <thead>\n                <tr>\n                    <th>Symptoms at the scene<\/th>\n                    <th>Possible reasons<\/th>\n                    <th>Recommended confirmation method<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td>The output pressure of the blower is gradually increasing.<\/td>\n                    <td>Leaking air plate blockage and scale build-up<\/td>\n                    <td>Compare the weekly stress record trends<\/td>\n                <\/tr>\n                <tr>\n                    <td>The pressure of the blower suddenly decreased<\/td>\n                    <td>Leaks from the breather plate or the pipes have been detected<\/td>\n                    <td>Check whether there is significant localized bubbling on the surface of the test pool.<\/td>\n                <\/tr>\n                <tr>\n                    <td>The surface of the pond is partially stirred up, and the bubbles are particularly large.<\/td>\n                    <td>The membrane rupture or the connector is loose<\/td>\n                    <td>Marking location, scheduling maintenance<\/td>\n                <\/tr>\n                <tr>\n                    <td>There are no bubbles in the pool surface.<\/td>\n                    <td>The area's air-blowing device is blocked or the pipeline is clogged.<\/td>\n                    <td>Confirm that the district control valve and piping are in place.<\/td>\n                <\/tr>\n                <tr>\n                    <td>Dissolved oxygen decreased but pressure remained normal<\/td>\n                    <td>Insufficient oxygen supply and increased load<\/td>\n                    <td>Check the flow rate and airflow settings<\/td>\n                <\/tr>\n                <tr>\n                    <td>After cleaning the surface, the pressure remains high.<\/td>\n                    <td>Airway obstruction<\/td>\n                    <td>Check the intake filter and piping for rust<\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n    <\/div>\n\n    <p class=\"wp-block-paragraph\">It is recommended to record the blower outlet pressure, operating current, and aeration tank dissolved oxygen at least once a week, and to take photos and save them when the bubble distribution on the surface of the tank changes. With continuous recording, it is possible to distinguish whether the blockage is gradually occurring or whether it has suddenly ruptured.<\/p>\n\n    <h2>How to reduce the blockage and rupture of the aeration disc?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>The key to reducing aeration disc failure is to avoid sludge recirculation, control the flow rate and temperature within the design range, and choose suitable materials and pore sizes based on the characteristics of the wastewater.<\/strong>It is recommended to follow the following points:<\/p>\n\n    <div class=\"dby-blockquote\">\n        <ol class=\"wp-block-list\">\n            <li>Choose exhaust equipment with a backflow prevention design to reduce sludge recirculation during shutdown.<\/li>\n            <li>Regularly replace the blower intake filter and check whether the air supply pipes are rusty.<\/li>\n            <li>Confirm that the airflow of each aeration disc is within the design range, and avoid excessive air supply in a single section.<\/li>\n            <li>Confirm that the material of the air supply duct and aeration plate can withstand the temperature of the exhaust air from the blower.<\/li>\n            <li>The material of the aeration disc should be selected based on the acid-base value, temperature, and chemical composition of wastewater.<\/li>\n            <li>Ensure the pipes are level and fixed during installation.<\/li>\n            <li>Establish regular records of blower pressure, current, and dissolved oxygen.<\/li>\n        <\/ol>\n    <\/div>\n\n    <h2>Which high SS or oil-containing wastewater can be selected that does not block the aeration equipment?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>Pool tanks with suspended solids, oil-containing or intermittent aeration are recommended to be evaluated with a counter-current design or an aeration system that does not rely on fine-pore aeration to reduce the frequency of clogging and downtime for cleaning.<\/strong>The non-blocking aeration equipment produced by Daibenying Co., Ltd. includes:<\/p>\n\n    <div class=\"dby-blockquote\">\n        <ul class=\"wp-block-list\">\n            <li><strong>Flow-through non-blocking coarse bubble dispersion plate<\/strong>Available in stainless steel (SUS+ABS) and nylon (nylon+ABS) materials, with an independent anti-backflow design. See the coarse bubble degassing disc product page for details.<\/li>\n            <li><strong>Rotary-type aeration balloon<\/strong>Two models: 168ST (SUS+ABS) and 168 (nylon+ABS). The ball rotates while aerating the water and stirring the bottom mud. The website indicates the single flow rate at 0.1\u20130.2 cmm, installation spacing 1 m \u00d7 1 m, and minimum water depth 50 cm.<\/li>\n            <li><strong>KTY888ST sewage energy-saving aerated oxygenation machine<\/strong>No need for an aeration disc or ducting; the official website indicates that the 2.5 HP model has a suction volume of 315 L\/min and a mixing depth of 3 m.<\/li>\n        <\/ul>\n    <\/div>\n\n    <p class=\"wp-block-paragraph\">For complete product information, please refer to the product page for non-blocking aeration equipment. For more information on choosing between coarse bubbles and fine bubbles, please read the related articles.<\/p>\n\n    <h2>Common problems<\/h2>\n\n    <!-- Q&A \u5340\u584a -->\n    <div class=\"dby-qa-container\">\n        <details class=\"dby-qa-item\">\n            <summary>Is it possible to keep cleaning the pool while the aeration disc is clogged?<\/summary>\n            <p>Some minor blockages can be improved by increasing the airflow for a short period (commonly known as \"blowing the tube\"). However, the effect is limited and it is necessary to ensure that the airflow does not exceed the capacity of the aeration tank. If the blockage is caused by hardened sludge or severe fouling, removal and cleaning or replacement are usually still required. For pools that are not easy to stop, when selecting the design, priority should be given to designs with low risk of blockage.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>How often do I need to replace the degassing disc?<\/summary>\n            <p>The replacement cycle for aeration discs depends on the material, wastewater characteristics, and operating conditions; there is no uniform lifespan. Data from the U.S. Department of Energy indicates that fine bubble membrane aeration devices need to be replaced every 8\u201312 years, but may need to be replaced more frequently in high-load or chemically-contaminated industrial wastewater. It is recommended to judge based on the pressure trend of the blower and observation results on the pond surface, rather than just looking at the number of years of use.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>What should be considered when restarting the blower after a power outage?<\/summary>\n            <p>Before restarting the blower after a power outage, it is necessary to first check whether the air duct is backfilled with sludge and observe whether the blower pressure is significantly higher after starting than before the outage. If the pressure rises abnormally, it may indicate that part of the aeration disc has been clogged with backfilled sludge. Air-blowing equipment with a backflow prevention system can reduce this risk.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>Does the increase in blower pressure necessarily mean that the aeration disc is blocked?<\/summary>\n            <p>Not necessarily. The increased pressure in the blower may also be caused by clogged intake filters, changes in the opening of the air supply pipes, an increase in the water level in the pond, or water accumulation in the pipes. Before determining the cause, it is necessary to rule out these factors and then check the bubble distribution in the pond to confirm whether the aeration system is blocked.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>What are the effects of a burst air valve?<\/summary>\n            <p>When the aeration disc breaks, air will be released in large quantities from the hole, forming localized turbulent bubbles. The oxygen transfer efficiency in the area will decrease significantly; the air output from other aeration discs on the same tube will also decrease. If the hole continues to expand, sludge may also enter the delivery tube from the hole, causing greater blockages in a wider area. If discovered, it is recommended to schedule repairs as soon as possible.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>Which material is more durable, stainless steel or nylon?<\/summary>\n            <p>Stainless steel and nylon have different applicable environments; there is no absolute ranking of durability. Stainless steel structures are strong and resistant to impact, while nylon is resistant to corrosion and lighter in weight. When choosing, the acid-base value, temperature, chemical composition, and pond conditions of the wastewater should be provided by the equipment manufacturer based on the actual environment.<\/p>\n        <\/details>\n    <\/div>\n\n    <!-- \u5e95\u90e8\u884c\u52d5\u547c\u7c72 (CTA) \u5340\u584a\uff1a\u6307\u5b9a\u6df1\u7da0\u8272\u80cc\u666f\u8207\u767d\u5b57 -->\n    <div class=\"blog-cta-box\">\n        <h3>Have Da Ben Ying Co. Ltd. assist in diagnosing the aeration disc problem<\/h3>\n        <p>If your aeration system is frequently clogged or broken, or the blower pressure continues to rise, please provide photos of the aeration tank, records of the blower pressure, and the nature of the wastewater. The Da Ben Ying Co. Ltd. Technical Team can help determine the cause and evaluate suitable non-clogging aeration equipment.<\/p>\n        <ul>\n            <li>Contact us: Da Ben Ying Co. Ltd. Contact Form<\/li>\n            <li>Email\uff1akty9002@gmail.com<\/li>\n            <li>Free phone number: 0800-216899<\/li>\n        <\/ul>\n        <a href=\"https:\/\/www.kty9002.com.tw\/paper\/contact_index.php?title_id=6593\" class=\"blog-cta-btn\">Go to fill out the consultation form<\/a>\n    <\/div>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u66dd\u6c23\u76e4\u70ba\u4ec0\u9ebc\u6703\u963b\u585e\u6216\u7834\u88c2\uff1f\u58d3\u640d\u3001\u6750\u8cea\u8207\u7dad\u8b77\u91cd\u9ede\u4e00\u6b21\u770b \u66dd\u6c23\u76e4\u963b\u585e\u6700\u5e38\u898b\u7684\u539f\u56e0\u662f\u505c\u6c23\u6642\u6c61\u6ce5\u56de\u6d41\u3001\u8868\u9762\u7d50\u57a2\u8207\u751f\u7269\u819c [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[18],"tags":[],"class_list":["post-1494","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/posts\/1494","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/comments?post=1494"}],"version-history":[{"count":2,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/posts\/1494\/revisions"}],"predecessor-version":[{"id":1498,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/posts\/1494\/revisions\/1498"}],"wp:attachment":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/media?parent=1494"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/categories?post=1494"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/tags?post=1494"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}