{"id":1509,"date":"2026-11-18T17:26:47","date_gmt":"2026-11-18T09:26:47","guid":{"rendered":"https:\/\/dby9002.com.tw\/?p=1509"},"modified":"2026-11-18T20:45:58","modified_gmt":"2026-11-18T12:45:58","slug":"odour-backflow-in-apartment-buildings","status":"publish","type":"post","link":"https:\/\/dby9002.com.tw\/en\/blog\/apartment-buildings-odor-backflow\/","title":{"rendered":"Odors from the building's toilets are seeping out; it's not necessarily just through the ventilation ducts: key analysis of joint piping inspection"},"content":{"rendered":"<div class=\"blog-post-container\">\n\n    <!-- \u6587\u7ae0\u5927\u6a19\u984c -->\n    \n    \n    <!-- \u5f15\u6587\u5340\u584a -->\n    <p class=\"dby-blockquote wp-block-paragraph\"><strong>The reason for the foul odor from the building\u2019s toilets may be due to stagnant water in the pipes, the water seal being dry or drained out, the drainage pipes not being properly connected, the pipes leaking between the pipes, the bathroom exhaust pipes being reverse-circulating, or the ventilation system not being able to properly vent the air from the roof. A ventilation fan can improve the ventilation between the pipes, but it cannot repair the broken seal of the stagnant water pipe or damaged pipes.<\/strong>Therefore, before addressing the odor problem, it is necessary to first conduct an on-site inspection of the common pipes to identify the true source of the odor, and then decide whether to install or replace the ventilation equipment.<\/p>\n\n    <p class=\"wp-block-paragraph\">This article summarizes the five common causes of odorous sewage from building toilets, the key points to check during inspection, and the role of ventilation fans in improving the solution.<\/p>\n\n    <h2>Why does the toilet in the building have a foul smell coming out?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>The foul odor from the building\u2019s toilets was due to odors from the drainage system or pipes, which found a way to enter the interior.<\/strong>Common paths include water leaks from the floor, the drain holes of the sink and toilet, the bathroom exhaust vents, and the gaps between pipes and the bathroom ceiling.<\/p>\n    \n    <p class=\"wp-block-paragraph\">The drainage pipes and pipes between buildings are usually shared by the entire building; a single household\u2019s problem may come from other floors; conversely, installing odor control equipment on an individual home may not necessarily solve the common pipe problem for the entire building. This is also why odor management often requires the community board and professional contractors to work together from the shared pipes.<\/p>\n\n    <h2>What are the five common causes of foul odors seeping out?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>The five most common reasons for odorous sewage leaking from building toilets are: a defective water trap that retains water, poor ventilation in the drainage pipes, leakage in the pipes between the pipes, a backflow in the bathroom exhaust pipes, and insufficient exhaust ventilation at the roof outlet.<\/strong><\/p>\n<div class=\"dby-content-box\">\n    <h3>The water in the water trough becomes dry or is drained out.<\/h3>\n    \n    <p class=\"wp-block-paragraph\"><strong>A retention ditch is a curved section of drainage pipe that retains a certain amount of water; when the water is blocked by a dam, the foul odor is prevented from escaping into the sewer; when the water is drained or completely drained, the foul odor will enter the interior directly from the drainage outlet.<\/strong>Floors that are not used for a long time will have water dripping from the top, and the dry area of a bathroom with a separate wet and dry area is most susceptible to drying out due to evaporation.<\/p>\n    \n    <p class=\"wp-block-paragraph\">Another situation is \"rainbow siphon failure\": when high-rise buildings drain heavily, negative pressure is generated in the drainage pipes, which causes water from other floors to be drawn into the water bends. This type of problem is usually related to poor ventilation in the pipes.<\/p><\/div>\n<div class=\"dby-content-box\">\n    <h3>Drainage pipes are not properly ventilated<\/h3>\n    \n    <p class=\"wp-block-paragraph\"><strong>Drainage pipes require vent pipes to balance the pressure inside the pipes. When the vent is not working properly, drainage can cause positive or negative pressure inside the pipes, pushing foul odors into the room or causing the water to be drained out completely.<\/strong>Blocked or clogged air ducts, or poorly designed roof outlets, can all lead to insufficient ventilation in the attic. If the odor is particularly noticeable in other floors when a large amount of water is being used, this reason should be a priority for investigation.<\/p><\/div>\n<div class=\"dby-content-box\">\n    <h3>Pipe connections or damaged pipes are leaking air<\/h3>\n    \n    <p class=\"wp-block-paragraph\"><strong>If the drainage pipes and ventilation pipes within the pipes are loose at the joints, the pipes are cracked, or the sealing at the wall is not complete, the foul odor will first leak into the pipes, then enter the various bathrooms through the gaps or exhaust pipes.<\/strong>The pipes in old buildings have been used for many years, and the probability of their fittings aging and breaking is higher.<\/p><\/div>\n<div class=\"dby-content-box\">\n    <h3>Bathroom exhaust duct backflow<\/h3>\n    \n    <p class=\"wp-block-paragraph\"><strong>The exhaust pipes in many buildings connect to common pipes; when a unit\u2019s exhaust fan is turned off or there is a flow of air that is not smooth within the pipes, the moisture and odors from other floors may be drawn back into the room through the exhaust pipes.<\/strong>The characteristic of such problems is that the foul odor originates from the air vent on the bathroom ceiling, rather than from the drainage hole.<\/p><\/div>\n<div class=\"dby-content-box\">\n    <h3>The roof exit has insufficient ventilation.<\/h3>\n    \n    <p class=\"wp-block-paragraph\"><strong>If the top of the pipes does not have sufficient exhaust capacity, the moisture and odors within the pipes will not be able to be discharged smoothly, and will accumulate inside the pipes and spread into the gaps in the floors.<\/strong>Roof-top outlets that are clogged with debris, have damaged original ventilation equipment, or are not rotating smoothly will all reduce the exhaust effect.<\/p><\/div>\n\n    <h2>What key points should be checked during the joint pipeline inspection?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>The joint pipeline inspection begins with the \"location and time of the odor occurrence,\" and then proceeds to check each household's drainage outlets, bathroom exhaust vents, and the internal pipes and roof outlets, gradually narrowing down the source of the odor.<\/strong><\/p>\n\n    <!-- \u8868\u683c\u5340\u584a\uff08\u624b\u6a5f\u7248\u53ef\u5de6\u53f3\u89f8\u63a7\u6ed1\u52d5\uff09 -->\n    <div class=\"dby-table-wrapper\">\n        <table class=\"dby-custom-table\">\n            <thead>\n                <tr>\n                    <th>Symptoms at the scene<\/th>\n                    <th>Possible reasons<\/th>\n                    <th>Key points of on-site inspection confirmation<\/th>\n                <\/tr>\n            <\/thead>\n            <tbody>\n                <tr>\n                    <td>Odour came from the water dripping from the floor head.<\/td>\n                    <td>The water trough dried up or the seal was broken<\/td>\n                    <td>Whether the foul odor disappears after adding water, and whether the water-soaked head has an anti-odour design<\/td>\n                <\/tr>\n                <tr>\n                    <td>The odor becomes more intense when water is used in other floors.<\/td>\n                    <td>Poor ductal ventilation and a ruptured sphincter<\/td>\n                    <td>Whether the ventilation duct reaches the roof and whether the outlet is blocked<\/td>\n                <\/tr>\n                <tr>\n                    <td>Odour came from the ventilation duct on the ceiling<\/td>\n                    <td>Reverse flow in the ventilation duct<\/td>\n                    <td>Is the exhaust duct connected to a common pipeline, and is there a design to prevent backflow?<\/td>\n                <\/tr>\n                <tr>\n                    <td>There is an odor in the bathroom ceiling.<\/td>\n                    <td>Leakage of air in the pipe between the pipes<\/td>\n                    <td>Repair the internal pipe connections and seal the gaps in the wall<\/td>\n                <\/tr>\n                <tr>\n                    <td>Multiple households are reporting simultaneously, and the humid season is worsening.<\/td>\n                    <td>Insufficient exhaust flow between pipes<\/td>\n                    <td>Is the ventilation equipment on the roof exit operating properly?<\/td>\n                <\/tr>\n                <tr>\n                    <td>The foul odor is concentrated around the toilet.<\/td>\n                    <td>Toilet seat base seal failed<\/td>\n                    <td>Is the toilet seat loose or leaking at the junction with the floor?<\/td>\n                <\/tr>\n            <\/tbody>\n        <\/table>\n    <\/div>\n\n    <p class=\"wp-block-paragraph\">During the on-site inspection, it is recommended to interview residents from multiple floors simultaneously. Record the time, weather, and location of the odor. If only one unit is experiencing problems, it is most likely an indoor issue; if multiple units are experiencing the same problem, priority should be given to checking the common pipes and roof exits.<\/p>\n\n    <h2>What role does a ventilation ball play in improvement programs?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>The ventilation ball is installed at the top of the pipes; its function is to remove the moisture and odors from the pipes to the roof, keeping upward-flowing air inside the pipes to reduce the chance of odors spreading to the various rooms.<\/strong>When problems arise from insufficient exhaust ventilation in pipes or backflow in bathroom exhaust ducts, improving the exhaust ventilation capacity of the roof outlet is often a crucial step.<\/p>\n    \n    <p class=\"wp-block-paragraph\">But a ventilation ball is not a universal solution. If the odor originates from a stagnant water puddle that has dried up, a broken pipe, or a seal on the toilet seat that has failed, these problems must first be repaired. Simply increasing the ventilation capacity cannot solve the underlying problem. The purpose of the current survey is to determine where the ventilation equipment should be placed in the improvement plan.<\/p>\n\n    <h2>What are the steps to improve the odours in the building's toilets?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>To improve the odours in the building\u2019s toilets, it is recommended to first eliminate indoor problems and then address the shared pipes. Finally, by verifying the roof\u2019s ventilation capacity, you can proceed in a way that avoids spending money without solving the problem.<\/strong>The suggested steps are as follows:<\/p>\n\n    <div class=\"dby-blockquote\">\n        <ol class=\"wp-block-list\">\n            <li>Please contact the resident first to turn on the water for long-term unused faucets, and observe if the odor improves.<\/li>\n            <li>Statistics reflect the characteristics of the units, locations, and time periods, which determine whether it is a single-unit or multi-unit problem.<\/li>\n            <li>Check whether the bathroom exhaust pipes are connected to a common pipeline, and whether there is a design to prevent backflow.<\/li>\n            <li>Open the pipe connection between the two pipes to check the pipe connections, damage, and the sealing condition of the wall.<\/li>\n            <li>Confirm that the drainage pipes and air vents are connected to the roof and that the outlets are unobstructed.<\/li>\n            <li>Check whether the ventilation equipment at the outlet of the roof pipes is operating properly.<\/li>\n            <li>Based on the current inspection results, repair the piping and assess the installation or replacement of ventilation equipment.<\/li>\n        <\/ol>\n    <\/div>\n\n    <h2>What situations are the Da Ben Ying Co. Ltd. Pipe Inter-Room Ventilation Ball suitable for?<\/h2>\n    \n    <p class=\"wp-block-paragraph\"><strong>Daiben Ying Co., Ltd. provides ventilation balls and exhaust fans for pipes in community buildings. They are designed for both electric and natural ventilation. They are made of 201 stainless steel and equipped with turbine exhaust blades that are installed at the outlet of the pipes in the building roof.<\/strong>The design allows for both electric and natural ventilation, ensuring that the equipment can still maintain exhaust ventilation with the help of the motor when there is no wind or insufficient wind power.<\/p>\n    \n    <p class=\"wp-block-paragraph\">These types of equipment are suitable for communities with insufficient exhaust ventilation between pipes or bathroom exhaust ducts that have reverse flow, or for multi-unit buildings with multiple complaints of dampness and odors. For product specifications, please refer to the Ventilation Products for Pipe Intersections page. Installation cases can be found in the installation examples by Da Ben Ying Co. Ltd.. If the board of directors is concurrently evaluating water tower equipment, please refer to the related articles for further reading.<\/p>\n\n    <h2>Common problems<\/h2>\n\n    <!-- Q&A \u5340\u584a -->\n    <div class=\"dby-qa-container\">\n        <details class=\"dby-qa-item\">\n            <summary>The toilet stinks; can installing a ventilation fan solve the problem?<\/summary>\n            <p>Not necessarily. A vent cap can improve the odor caused by insufficient exhaust ventilation between pipes. However, if the odor originates from a stagnant water puddle that has dried up, a drainage pipe that is damaged, or a toilet seat seal that is defective, these problems must first be repaired. It is recommended to first conduct a joint pipe inspection to confirm the source of the odor, and then decide whether to install or replace the ventilation equipment.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>Only my house has an odor; is it a problem with the shared pipes?<\/summary>\n            <p>When only one household has a foul odor, it is most likely a problem with the indoor facilities, such as a clogged drain, poorly designed water retention basins, or a defective toilet seal. It is recommended to first water the drain and inspect the surrounding area of the toilet. If this still does not improve, please ask the board of directors to assist in inspecting the pipes connecting to the household and the exhaust pipes.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>Why does my house smell bad when water is being used in other floors?<\/summary>\n            <p>This usually indicates poor drainage in the plumbing system. When a large amount of water drains from other floors, the pressure changes in the pipes can cause water to be drawn back into the water tank or the foul odor to be carried into the room. It is recommended to check whether the drainage pipes are connected to the roof and whether the outlets are blocked. If necessary, a professional contractor will assess the best way to improve the situation.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>The ventilation outlets on the bathroom ceiling have an unpleasant odor. What is the cause?<\/summary>\n            <p>Odour issues in ceiling exhaust vents are usually caused by reverse flow in the exhaust pipes. If the bathroom exhaust pipes are connected to a common duct, when the home\u2019s exhaust fan is turned off and the air flow in the ducts is insufficient, moisture and odors from other floors may be drawn into the exhaust duct. You can check whether the exhaust pipes have anti-reverse flow design and confirm the capacity of the roof outlet.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>Do ventilation fans need electricity?<\/summary>\n            <p>Ventilation balls come in pure natural ventilation models and electric and dual-purpose models. The pure natural ventilation model relies on wind and thermal buoyancy to rotate the exhaust fan; it does not require electricity. The electric and dual-purpose models, on the other hand, use a motor to maintain exhaust flow when there is no wind or insufficient wind. The Da Ben Ying Co. Ltd. duct ventilation ball is a dual-purpose model that combines electric and natural ventilation.<\/p>\n        <\/details>\n\n        <details class=\"dby-qa-item\">\n            <summary>The community needs to replace the ventilation fan. What documents do I need to prepare?<\/summary>\n            <p>It is recommended that you prepare the number and location of duct connections, the dimensions and photos of the roof outlets, the type of existing ventilation equipment, and the floor and time records of any complaints about odors from residents. The more complete the data, the better you can determine whether equipment needs to be replaced and the appropriate specifications and quantities.<\/p>\n        <\/details>\n    <\/div>\n\n    <!-- \u5e95\u90e8\u884c\u52d5\u547c\u7c72 (CTA) \u5340\u584a\uff1a\u6307\u5b9a\u6df1\u7da0\u8272\u80cc\u666f\u8207\u767d\u5b57 -->\n    <div class=\"blog-cta-box\">\n        <h3>Have Da Ben Ying Co. Ltd. assist in checking the pipes in the existing building.<\/h3>\n        <p>If multiple units in a community building are experiencing issues with odor or humidity in the toilets, please provide the location of the pipes, photos of the roof outlets, and any records of the residents' complaints. Da Ben Ying Co. Ltd. can help assess the ventilation situation and improve the ventilation system.<\/p>\n        <ul>\n            <li>Contact us: Da Ben Ying Co. Ltd. Contact Form<\/li>\n            <li>Email\uff1akty9002@gmail.com<\/li>\n            <li>Free phone number: 0800-216899<\/li>\n        <\/ul>\n        <a href=\"https:\/\/www.kty9002.com.tw\/paper\/contact_index.php?title_id=6593\" class=\"blog-cta-btn\">Go to fill out the consultation form<\/a>\n    <\/div>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u5927\u6a13\u5ec1\u6240\u7570\u5473\u5012\u704c\u7684\u539f\u56e0\uff0c\u53ef\u80fd\u4f86\u81ea\u5b58\u6c34\u5f4e\u6c34\u5c01\u4e7e\u6db8\u6216\u88ab\u62bd\u4e7e\u3001\u6392\u6c34\u7acb\u7ba1\u901a\u6c23\u4e0d\u826f\u3001\u7ba1\u9053\u9593\u7ba1\u7dda\u6f0f\u6c23\u3001\u6d74\u5ba4\u6392\u98a8\u7ba1\u9006\u6d41\uff0c\u6216\u5c4b [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[18],"tags":[],"class_list":["post-1509","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"_links":{"self":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/posts\/1509","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/comments?post=1509"}],"version-history":[{"count":2,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/posts\/1509\/revisions"}],"predecessor-version":[{"id":1521,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/posts\/1509\/revisions\/1521"}],"wp:attachment":[{"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/media?parent=1509"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/categories?post=1509"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dby9002.com.tw\/en\/wp-json\/wp\/v2\/tags?post=1509"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}