The trend towards stricter water quality standards: What should the electroplating, slaughtering, and meat processing industries first consider?
On December 18, 2011, the Ministry of Environmental Protection revised and issued the Standard for Wastewater Discharge, tightening regulations for ammonia nitrogen, total phosphorus, copper, and free effective residual chlorine in certain industries. The tightened requirements for existing businesses will apply starting January 1, 2016.The electroplating industry should prioritize the concentration of copper in wastewater and the ability to treat chemical sediment; meat and meat product retailers should prioritize the nitrogen-ammonia ratio and the nitrification ability of biological treatment. The sooner data is compared and gaps are identified, the more time there is to plan improvements.
This article summarizes the key points of this water discharge standard revision, the items that each industry should first consider, and the potential impacts of stricter regulations on aeration and sludge treatment. The official regulatory content is based on the Environmental Protection Agency’s announcement.
What has this water release standard been revised to?
The main focus of this revision of the discharge standards is to tighten the requirements for four categories of substances: ammonia nitrogen, total phosphorus, copper, and free effective residual chlorine, specifically for certain industries, in order to reduce the load of ammonia nitrogen and high concentrations of phosphorus in wastewater entering the water body, and continuously reduce the copper concentration in specific watersheds.
According to the instructions provided by the Ministry of Environmental Protection during the preliminary phase and the promotional materials provided by the local environmental protection bureaus, the main industries involved in each project are as follows:
| Strengthened projects | Mainly related to industry | Direction of control |
|---|---|---|
| Ammonia nitrogen (NH₃-N) | Leather, printed circuit boards, slaughtering, meat markets, medical institutions, etc. | Expand the scope of the industry and tighten the limits |
| Total phosphorus (TP) | Semiconductor, optoelectronic materials, industrial zone sewage drainage systems, etc. | Additional or stricter controls |
| Copper (Cu) | Electropolishing, metal surface treatment, jewelry manufacturing, industrial zones and science parks, etc. | Strengthen the limit values |
| Free and effective residual chlorine | Hospitals, public sewage and drainage systems, etc. | New upper limit to avoid excessive chlorination |
According to a report by the Central News Agency, when the draft was announced in August 2011, the Ministry of Environmental Protection estimated that the amendments would affect more than 3,500 businesses, of which about 2,100 would be affected by the copper control, and about 850 by the ammonia nitrogen control (source:Xinhua News Agency[cite: 1]. The actual limits applicable to different industries will vary depending on the size of the water volume that has been established or newly established, please refer to the attached regulations for details.
When will existing operators start applying the new standards?
The information materials from the Environmental Protection Bureau of Nantou County indicate that the tightened water discharge standards will take effect on January 1, 2016, affecting industries such as metal surface treatment, electroplating, slaughtering, meat markets, and leather.In addition, the Ministry of Environmental Protection stated in the preliminary phase that ammonia nitrogen and total phosphorus would be managed in stages; the stricter targets for some projects would be extended until around 2030 (source:Environmental Protection Bureau of Nantou County Government、Xinhua News Agency[cite: 1].
In other words, it is not long until the applicable date comes. If existing processing facilities need to be expanded or improved, it takes time from evaluation, design, procurement, to trial operation. The earlier the planning is done, the better it will be to avoid rush work.
What should the electroplating industry first consider?
The main tightening measures facing the electroplating industry are copper. It is necessary to prioritize monitoring the concentration of copper discharged into the water over the past year, the periods when the concentration exceeds the standard, or is close to it, and whether the chemical precipitation treatment unit can stably reach the new limit value.
Specifically, the electroplating industry can be divided into four categories:
- Test dataThe water quality monitoring report for the past 12 months was extracted to find the average and maximum copper concentrations, and compared with the new standard tables.
- Waste water flowWhether copper-containing wastewater is collected with other wastewater flows; mixing will increase the difficulty of treatment.
- Complex interferenceThe alloying agent in the plating solution makes it difficult to remove copper by chemical precipitation. If a process involving alloying agents is used, it should be evaluated whether pre-treatment such as dealloying is necessary.
- Variation in sludge volumeAfter the copper removal is completed, the amount of chemical sludge may increase; it is necessary to verify whether the treatment capacity of the existing sludge dehydration equipment is sufficient.
For a complete treatment plan for the electroplating industry, please refer to the Electroplating Wastewater Treatment Industry page.
What should slaughtering and meat processing companies first assess?
The main tightening measures faced by the slaughter and meat market industry are ammonia nitrogen levels, with priority given to assessing the ammonia nitrogen concentration in wastewater, as well as the nitrification capacity of biological treatment systems and whether aeration and oxygen supply are sufficient.
Slaughterhouse and meat processing wastewater contains large amounts of blood water, proteins, and fats. During treatment, organic nitrogen is converted into ammonium nitrogen. To stably remove ammonium nitrogen, biological treatment usually requires the nitrification reaction. This reaction requires sufficient dissolved oxygen, sufficient residence time, appropriate alkalinity, and water temperature. According to the chemical calculation of the nitrification reaction, theoretically, about 4.57 grams of oxygen are required for every 1 gram of ammonium nitrogen; therefore, stricter control of ammonium nitrogen often directly increases the aeration requirement.
It is recommended that slaughterhouses and meat businesses prioritize confirmation:
- Over the past year, the ammonia nitrogen concentration in the discharge water has shown seasonal changes.
- It is unknown whether the aerated pool's dissolved oxygen is sufficient to support the nitrification reaction.
- The duration of biological treatment and the age of the sludge are sufficient.
- Whether the lipid and SS pre-treatment are stable and avoid affecting the biological treatment.
- After the biological treatment is enhanced, is the sludge production and dehydration capacity sufficient?
For processing planning in the slaughtering industry, please refer to the Slaughtering/Electric Slaughterhouse Wastewater Treatment Industry page.
What are the recommended steps for monitoring and improving?
In the face of stricter water discharge standards, it is recommended to proceed in the order of “comparing data, identifying gaps, inventorying facilities, and setting a timeline”; first confirm the severity of the problem, then decide on the scale of improvement.
- Nearly 12 months of water discharge monitoring reports have been obtained.
- According to the industry category, whether existing or newly established, and the scale of waste water volume, the applicable limits of the new standard tables are compared.
- Items and time periods that exceed or are close to the standard are marked.
- Review the design capacity and actual load of each processing unit.
- Evaluate whether the aeration and oxygen supply capacity for sludge treatment needs to be expanded.
- Plan improvement programs, budgets, and construction schedules.
- Confirm whether the change in the confirmation processing facility requires the modification of the relevant permit documents for water pollution control, and communicate in advance with the relevant authorities.
| Industry | Mainly tightened items | Priority consideration | Possible affected processing units |
|---|---|---|---|
| Electrophoresis, metal surface treatment | 銅 | Copper concentration in wastewater and use of chelating agents | Chemical precipitation and sludge dehydration |
| Slaughtering and meat market | Ammonia nitrogen | Ammonia nitrogen in wastewater, dissolved oxygen in aeration tank | Biological treatment, aeration, sludge dehydration |
| Leather | Ammonia nitrogen | Ammonia nitrogen in wastewater and pre-treatment | Biological treatment and aeration |
After the water discharge standards are tightened, what impact will aeration and sludge treatment have?
After stricter water discharge standards were implemented, the most common side effects were increased aeration requirements and increased sludge production: the removal of ammonia nitrogen requires more oxygen supply, while copper removal may produce more chemical sludge.
Regarding aeration, if your existing aeration equipment is nearing full capacity or the ventilation system is clogged or damaged, you should first diagnose the current situation and then evaluate whether to expand or replace it. For more information, please refer to the relevant articles.
In the case of sludge, after the sludge volume increases, the original dehydration equipment may need to be operated for longer hours or have its processing capacity expanded.
What equipment can Da Ben Ying Co. Ltd. help evaluate?
Daiben Ying Co., Ltd. is a wastewater treatment equipment manufacturer based in U-Ying District, Taichung City. Their products include HS500 and HS800 horizontal slitter sludge dewatering machines and non-blocking aeration equipment. Their installation cases include industries such as electroplating, food processing, and livestock farming.As the discharge water standards tighten, Da Ben Ying Co. Ltd. can help assess whether the sludge dewatering and aeration equipment needs to be expanded or replaced.
For related products, please refer to HS500 Sludge Dewatering Machine, HS800 Sludge Dewatering Machine, and Non-blocking Aeration Equipment. For regulatory compliance and permit documentation issues, it is recommended to consult the relevant environmental authorities or environmental consultants simultaneously.
Common problems
When was the standard for the discharge water revised?
The most recent revision of the Water Discharge Standards was issued on December 18, 2011. This revision tightened the regulations for ammonia nitrogen, total phosphorus, copper, and free effective residual chlorine in certain industries. The stricter requirements for existing operators will apply starting January 1, 116. For the actual limit values and applicable conditions for each item, please refer to the provisions and tables published in the Environmental Ministry’s Regulations System Announcement.
Are the standards for new and existing operators the same?
Not necessarily. The limits in the Discharge Standard often vary depending on existing or newly established regulations and the scale of the waste water volume. Some items also have a phased tightening schedule. Businesses should refer to the applicable sections in the regulatory appendix based on their own establishment conditions and waste water volume, rather than directly applying the numbers of other businesses.
Why is copper from electroplating wastewater not easy to process?
Copper in electroplating wastewater often combines with chelating agents to form stable complexes, making conventional chemical precipitation methods difficult to remove copper. If the process uses a chelating agent-containing plating solution, pre-treatment such as dechelation is usually required first, followed by precipitation. It is recommended to first analyze the source and composition of the copper-containing wastewater and then evaluate the treatment method.
Why does the increase in ammonia nitrogen lead to an increased need for aeration?
Ammonia nitrogen usually needs to be removed through the nitrification reaction in biological treatment, which requires a large amount of oxygen. Chemically speaking, theoretically, for every 1 gram of ammonia nitrogen, approximately 4.57 grams of oxygen is required; therefore, after ammonia nitrogen control is tightened, the oxygen supply requirement of the aeration tank often increases. Operators should confirm whether the existing aeration equipment has sufficient headroom.
How long will it take to improve the processing facilities?
The time required for improvement depends on the scale of the improvement. From assessment of the current situation, program design, equipment procurement, construction, to trial operation, each phase requires time. If it involves changing permit documents, administrative procedures also need to be reserved for time. The date of application on January 1, 116 is not far away; it is recommended to complete the inventory as soon as possible and set a timeline.
The water quality testing data is close to the standard; should it be improved?
Recommendation for evaluation. Water quality in the discharge stream may fluctuate depending on production volume, season, and operating conditions. If the average value has already approached the new standard, the peak periods may exceed the limit. It is recommended to assess the risk by evaluating the highest value over the past year and the range of variation, and to reserve appropriate leeway for handling.
Have Da Ben Ying Co. Ltd. help assess the equipment needs after the tightening of regulations.
If you are facing stricter discharge water standards and need to assess whether the sludge dewatering or aeration equipment is sufficient, please provide the industry, wastewater volume, test data for the past year on discharge water, and the existing treatment process. The Da Ben Ying Co. Ltd. technical team can assist in reviewing the equipment capacity and improving directions.
- Contact us: Da Ben Ying Co. Ltd. Contact Form
- Email:[email protected]
- Free phone number: 0800-216899