To verify the energy savings achieved by aeration, it is necessary to compare actual electricity consumption before and after the process using the same water quality and oxygenation target, and to standardize the process based on the treated water volume or pollution load.Comparing horsepower figures alone, or looking at data for just a few days, or improving figures for different seasons and yields may all lead to distorted energy-saving figures.
This article explains which items to measure for air-tightness energy verification, how long the observation period should be, common error comparison methods, and provides a calculation example that can be directly applied.
Why is energy efficiency in air conditioning often "unclear"?
It is difficult to clearly explain the energy savings achieved through aeration because the electricity used for aeration is affected by the flow rate of the incoming water, organic load, water temperature, and the method of controlling dissolved oxygen. Without fixed comparison conditions, it is impossible to determine whether the decrease in electricity consumption is due to improvements in equipment or a reduction in load.
For example, after improvement, the season just happens to be off, production decreases, inflow load decreases, and electricity consumption naturally decreases; or before improvement, dissolved oxygen control is at 3 mg/L, but after improvement it only remains at 1.5 mg/L, electricity consumption also decreases, but the water quality may deteriorate accordingly. These are not energy-saving measures brought by the equipment itself.
The commonly used international method for measuring and verifying energy efficiency is IPMVP (International Performance Measurement and Verification Protocol), maintained by the Efficiency Valuation Organization (EVO). The core concept is to first establish a baseline period and then adjust it based on differences in conditions (source:EVO IPMVP[cite: 1]. Internal factory verification does not necessarily have to use the full IPMVP package, but the logic of “baseline period + condition adjustment” applies equally.
What items should be measured during the gas-tightness energy verification?
The energy efficiency verification of aeration systems requires measuring at least four types of data: electricity consumption, dissolved oxygen, wind flow, and the amount of water used to represent the processing load and the water quality.If any one of the categories is missing, the results of the comparison are easily questioned.
| Measurement items | Recommended tools | Recommended frequency | Notes |
|---|---|---|---|
| Using electricity consumption (kWh) | Dedicated meter for aeration equipment | Daily record cumulative value | Do not use horsepower figures or brand name power ratings to estimate |
| Dissolved oxygen (DO) | Dissolved oxygen meter | Fixed location and fixed time, at least 2 times a day | The measured points and depth before and after must be consistent. |
| Wind speed | Operation records of the wind speed meter or blower | Daily record | When changing the frequency of the blower or opening the valve, it is necessary to record the details. |
| Flow rate of water | Flowmeter | Total daily count | As a standard for standardized power usage |
| COD/BOD inflow | Laboratory analysis | At least once a week | Reflects changes in organic load |
| Water quality | Laboratory analysis | According to the routine testing frequency | Confirm energy saving without sacrificing processing performance |
| Water temperature | Thermometer | Daily record | Water temperature affects dissolved oxygen saturation and biological activity |
Why can't energy savings be calculated using horsepower?
The horsepower number is the rated power of the equipment; it is not equal to the actual power consumption; actual power consumption will vary depending on the load, operating time, and the frequency converter settings.Replacing a 15 HP unit with a 10 HP unit does not necessarily mean that electricity consumption will be reduced by one-third, because the actual load rate of the two devices may differ during operation. The correct approach is to install an electric meter in the aeration equipment circuit and directly compare the actual values.
How should dissolved oxygen be measured to provide a more reliable reference?
Oxygen dissolved must be measured at the same point, at the same depth, and during the same time period; only by comparing the results from before and after can the improvement be judged.The dissolved oxygen difference between different locations of the aeration tank can be significant; the higher the location near the diffuser, the lower the angle of the tank; dissolved oxygen levels also drop during peak flow periods throughout the day. It is recommended to mark fixed measurement points at the edge of the tank in advance and record them daily at fixed times.
How long should the observation period be?
The baseline period before improvement and the validation period after improvement should cover the entire production cycle of the factory, and the length of the two periods and the seasonal conditions should be as close as possible.In practice, each period covers at least several weeks of continuous data, which can more effectively rule out one-day fluctuations than looking at only a few days.
When choosing the observation period, it is recommended to pay attention to three things:
- Avoid abnormal periodsFor days when equipment malfunctions, production lines are shut down, or water quality is abnormal, they should be recorded and analyzed separately.
- Covering the entire production cycleIf the factory has differences between weekdays and weekends, peak seasons and off-seasons, the observation period should cover these changes.
- Similar seasonal conditionsWater temperature can affect the solubility of oxygen and the microbial activity in water; the aeration requirements may be different in summer and winter.
How to calculate the aeration energy efficiency?
The energy efficiency of aeration should be calculated using the "unitized treatment volume consumed" method; for example, the kWh/m³ consumption of electricity used to treat 1 cubic meter of water, or the kWh/kg COD removal rate (kWh/kg COD).Comparing the electricity usage using units eliminates the influence of production increases or decreases.
The following is an example of calculation (the figures are hypothetical, not specific to a particular case):
| Item | Baseline (before improvement) | Verification period (after improvement) |
|---|---|---|
| Number of observation days | 30 days | 30 days |
| Air-blown power supply | 9,000 kWh | 6,600 kWh |
| Amount of water processed | 18,000 m³ | 19,800 m³ |
| Unitized electricity usage | 0.50 kWh/m³ | About 0.33 kWh/m³ |
| Average dissolved oxygen | 2.1 mg/L | 2.2 mg/L |
| Water quality | Complying with standards | Complying with standards |
In this demonstration, the improved unit’s electricity consumption decreased from 0.50 to approximately 0.33 kWh/m³, resulting in a energy efficiency improvement of approximately 33%. At the same time, the dissolved oxygen and wastewater quality remained similar, confirming that the reduction in electricity consumption was due to improvements in the equipment rather than a reduction in treatment standards. If only the total electricity consumption (9,000 → 6,600 kWh) were compared, an estimated 27% reduction would be calculated, which would underestimate the improvement effect because the treated water volume increased by 10% during the verification period.
What are the steps for gas-tightness energy verification?
The energy efficiency verification of aeration can be carried out in five stages: defining the scope, establishing standards, implementing improvements, comparing conditions, and compiling reports.The suggested steps are as follows:
- Define the verification scope and confirm the equipment to be compared with the corresponding meter.
- Special meters are installed in the aeration equipment circuit to ensure that no other load is mixed in.
- Mark the fixed oxygen measurement point, depth, and measurement time.
- Record the electricity consumption, dissolved oxygen, wind volume, water volume, water quality, and water temperature for the collection reference period.
- Improve the execution equipment and record the dates of construction and adjustments.
- Once the waiting system is stable, start collecting records of verification periods of the same length.
- Comparing the power consumption using unitized quantities, it was confirmed that the dissolved oxygen and effluent quality were similar.
- Compile a comparison report, indicating the excluded abnormal dates and reasons.
Which aeration improvements are common in energy efficiency assessments?
Common energy-saving aeration improvements include replacing blocked or aging aeration equipment, reconfiguring coarse and fine bubbles based on pond function, switching to aeration equipment that is not dependent on aeration discs, and introducing dissolved oxygen control.The direction of improvement should start with an assessment of the current situation, such as whether the blower pressure is too high or whether the exhaust air is uneven.
Daibenying Co., Ltd. produces non-blocking aeration equipment, including flow-through non-blocking coarse bubble dispersion discs, tornado-type aerators, and KTY888ST sewage energy-saving aerator without an aeration disc and air duct. When evaluating replacement, it is recommended to establish measurement records before and after the improvement based on the methods in this article to confirm the energy-saving effect using actual data.
Common problems
Is it necessary to install an electricity meter for venting energy efficiency testing?
It is recommended to install the air compressor. If the aeration equipment shares a meter with other equipment, the electricity consumption changes may be due to other loads; it is not possible to determine the effect of the air compressor improvement independently. The cost of dedicated meters is usually much lower than the investment risk caused by erroneous judgment; if it is temporarily not possible to install them, at least periodic measurements of the current should be taken with a multimeter and operating hours recorded.
After improvement, the dissolved oxygen level increases, can this be considered energy-saving?
Higher dissolved oxygen levels indicate improved oxygen supply capacity, but this does not necessarily mean energy savings. If dissolved oxygen levels are higher than required for processing, the airflow or operating time can be further reduced to convert the excess oxygen supply capacity into electricity savings. When verifying this, the electricity consumption should be compared under the same dissolved oxygen target to obtain reliable energy savings figures.
How much data should be collected for the baseline period?
The baseline period should cover the entire production cycle of the factory. In practice, continuous records should be collected for at least several weeks. If there are significant differences between the busy and low-season periods, it is recommended to compare them in similar seasons or to collect data over a longer period for adjustment. The more complete the baseline period is, the less likely it is for the improvements to be questioned.
Can the data for winter and summer be compared directly?
Direct comparisons are not recommended. Water temperature can affect the solubility of oxygen and microbial activity in the water. The aeration requirements may differ between summer and winter. If comparisons are to be made across seasons, water temperature should be recorded simultaneously and the impact of seasonal differences should be explained in the report.
Using less electricity has reduced the water quality, but does that count as energy saving?
It is not truly energy-efficient. The purpose of aeration is to maintain the treatment effect; if electricity consumption decreases due to insufficient oxygen supply and poor treatment efficiency, it may instead lead to the risk of the treated water not meeting quality standards. Energy efficiency certification must simultaneously ensure that the water quality remains at the same level.
What should the energy-saving verification report include?
The energy efficiency verification report should include the scope of verification, the reference period and the verification period date, the measurement items and locations, the original data, the standardized calculation method, the dates and reasons for exclusion of abnormal results, and the comparison results of dissolved oxygen and effluent quality. The data must be complete and the methodology transparent, so that the report can serve as a basis for internal decision-making or subsequent investment.
Have Da Ben Ying Co. Ltd. assist in planning the aeration energy assessment
If you are considering replacing your aeration equipment or improving energy efficiency, please provide the current specifications of your blower, electricity usage records, pool size and water quality data. The Da Ben Ying Co. Ltd. Technical Team can assist in reviewing the current situation and planning the measurement methods before and after improvement.